    Fire safety
    With the acceleration of urban modernization, more and more large-scale buildings, public gathering places and high-rise buildings have been built, and the electricity consumption has risen sharply. At the same time, the number of cables in buildings
  • Solution
  • System architecture
  • Application cases
  • Recommended products
  • Solution to Electrical Fire

        The new generation of electric fire monitoring system developed by Easter meets all the requirements of the new national standard GB14287-2014 and is certified by CCCF Fire 3C. The system is composed of electric fire monitoring equipment and combined electric fire detector. It is used in 0.4kV low voltage distribution system to monitor the residual current, temperature and other important parameters. If the monitored parameters exceed the alarm set value, the system can send out sound and light alarm signals to detect hidden dangers in time and prevent electric fire.

        Compared with the old system, the communication distance of the new electric fire monitoring system is obviously longer, and it can communicate stably in the range of 2 km. The communication bus is designed by non-polar bus and supports star connection, which can greatly reduce the amount of field communication bus, reduce the failure rate of wiring and reduce the construction cost. It is very suitable for business complexes, high-end communities, schools, hotels, industrial plants and other occasions.


    Meet the criteria:

    GB 14287.1-2014 "Part 1 Electrical Fire Monitoring Equipment"

    GB 14287.2-2014 "Part 2 Residual Current Electric Fire Monitoring Detector"

    GB 14287.3-2014 "Part 3 Temperature-measuring Electrical Fire Monitoring Detector"

    GB 50016-2014 Code for Fire Protection in Architectural Design

    GB 50116-2013 Code for Design of Automatic Fire Alarm System

    GB 16838-2005 "Environmental Test Method and Strictness Grade of Fire-fighting Electronic Products"


    Solution of Power Supply Monitoring for Fire Fighting Equipment

        The EM770-B fire fighting equipment power supply monitoring system developed by our company is designed and developed according to the national standard GB28184-2011 "fire fighting equipment power supply monitoring system". The system consists of power supply monitor, current signal sensor, voltage signal sensor, current/voltage signal sensor and so on. Through the sensor, the main power supply and standby power supply of the fire fighting equipment are continuously detected 24 hours in real time, so as to judge whether the power supply equipment has overvoltage, undervoltage, overcurrent and circuit break. Faults such as short circuit and missing phase. When the fault occurs, the sensor quickly uploads the signal to the monitor, records the type and time of the fault location, and sends out the sound and light alarm signal, thus effectively guaranteeing the normal operation of the fire fighting system and improving the reliability of the fire fighting system.


    Meet the criteria:

    GB 25506-2010 General Technical Requirements for Fire Control Room

    GB28184-2011 "Power Supply Monitoring System of Fire Fighting Equipment"

    GB 50016-2006 Code for Fire Protection in Architectural Design

    GB50116-1998 Code for Design of Automatic Fire Alarm System


    Solution of Fire Door Monitoring System

       Our company has designed and developed EM series fire door monitoring system according to the relevant laws and standards of our country. The system consists of fire door monitor installed in fire control, fire door monitor extension installed in each district, door magnetic switch installed on fire door, electric door closer and other components. It can monitor the status of fire door in real time and form an automatic fire door monitoring network.


    Meet the criteria:

    GB29364-2012 Firedoor Monitor

    GB16838-2005 "Environmental Test Method and Strictness Grade of Fire-fighting Electronic Products"

    GB50016-2014 Code for Fire Protection in Architectural Design

    GB50116-2013 Code for Design of Automatic Fire Alarm System

    GB25506 General Technical Requirements for Fire Control Room

    Solution of Electrical Fire Monitoring

    Solution of Power Supply Monitoring for Fire Fighting Equipment

    Solution of Fire Door Monitoring System



       Shandong Cultural and Art Center        

           Dalian Red Star Mei Kailong


    Electrical fire monitoring system


    EM761-B

    EM721D

    EM720FA



    Power Supply Monitoring System of Fire Fighting Equipment


    EM770-B

    EM730


    Fire door monitoring system


    EM780-B

    FDA-C

    FDA-M



    VIDEO